-50%

Pentair Membrane

Original price was: ₹1,500.00.Current price is: ₹750.00.

Pentair Membrane is designed for high-efficiency water purification. It removes dissolved salts, bacteria, and contaminants while ensuring consistent water flow. Ideal for homes and commercial RO systems, this membrane improves water taste, quality, and safety.

Description

Pentair Membrane – Premium RO Water Purification Solution


Pentair Membrane ensures pure, safe water with high TDS removal. Durable and reliable for domestic & commercial RO systems. Call 8860202040 for support.


Product Advantages :

  • High TDS Removal Efficiency: Pentair membranes remove up to 99% of dissolved salts and harmful contaminants, ensuring safe drinking water.

  • Durable & Long-lasting: Engineered with advanced materials for extended membrane life, reducing frequent replacements.

  • Consistent Water Flow: Maintains uniform water output for uninterrupted clean water supply.

  • Energy Efficient: Operates at optimal pressure, saving electricity and reducing system load.

  • Wide Compatibility: Compatible with most domestic and commercial RO systems, making installation and replacement hassle-free.

  • Easy Maintenance: Requires minimal cleaning, lowering downtime and service costs.

  • Health & Safety: Protects against bacteria, viruses, and chemicals while retaining essential minerals when paired with post-filters.

  • Trusted Brand: Pentair is a global leader in membrane technology, ensuring reliability and performance.

  • Eco-Friendly: Efficient water recovery reduces wastewater, supporting environmental sustainability.

  • Cost-Effective: Reduced maintenance and longer life make it a budget-friendly purification solution.


Highlights & Specifications

Specification Details
Model Pentair RO Membrane
Type Thin Film Composite (TFC)
Capacity 50–200 LPD (model-dependent)
TDS Rejection Up to 99%
Operating Pressure 15–30 psi
Operating Temperature 5–45°C
pH Range 4–11
Salt Rejection 96–99%
Membrane Life 2–3 years (based on usage)
Material Polyamide Thin Film Composite

Product Customer Care Number

For any queries or support regarding Pentair Membrane, contact our expert team at 8860202040. We provide assistance for installation, troubleshooting, and routine maintenance.


Do’s & Don’ts

Do’s:

  • Flush membrane before first use to remove preservatives.

  • Use pre-filters to protect and extend membrane life.

  • Maintain recommended water pressure for optimal operation.

  • Follow routine service schedule for peak efficiency.

Don’ts:

  • Avoid exposing the membrane to chlorine or oxidizing agents.

  • Never run the RO system dry without water.

  • Do not use harsh chemicals or detergents for cleaning.

  • Do not exceed recommended operating temperature or pressure.


Product Repair & Troubleshooting

  • Low Water Output: Inspect inlet water pressure and pre-filters; replace clogged filters.

  • Off Taste or Odor: Flush membrane or replace if beyond lifespan.

  • Leaks: Check RO housing and seals; tighten or replace if necessary.

  • Frequent System Shutdown: Check pump pressure and reject flow; clean sediment filters.


Product Service Guide & Future Service Schedule

  • Routine Service: Every 6–12 months, depending on usage and water quality.

  • Membrane Replacement: Every 2–3 years for consistent performance.

  • Filter Check: Sediment and carbon pre-filters should be replaced every 4–6 months.

  • Maintenance Tip: Schedule professional service to prevent scaling and maintain optimum purification.

  • Performance Monitoring: Regularly test TDS and water flow for early detection of issues.


Product Installation Guide

  1. Turn off water supply before installation.

  2. Remove old membrane from RO housing.

  3. Flush new Pentair membrane with clean water for 10–15 minutes.

  4. Insert membrane into housing carefully, ensuring proper fit.

  5. Reconnect inlet/outlet tubes and check for leaks.

  6. Turn on water supply, discard initial storage water, and let system stabilize.

  7. Verify purified water quality using TDS meter or taste.


FAQs :

Q1: How often should I replace Pentair Membrane?
A1: Typically every 2–3 years, depending on usage and water quality.

Q2: Is it suitable for high TDS water?
A2: Yes, it efficiently removes up to 99% of dissolved salts.

Q3: Can I use it in all RO systems?
A3: It is compatible with most domestic and commercial RO systems.

Q4: How do I know the membrane needs replacement?
A4: Signs include low water output, off taste, odor, or high TDS levels.

Q5: Can I clean the membrane myself?
A5: Minor flushing is okay, but professional service is recommended.

Q6: Does it require electricity?
A6: The membrane itself is passive; the RO system pump provides pressure.

Q7: How can I extend the life of the membrane?
A7: Use pre-filters, maintain proper pressure, and schedule routine maintenance.

To know more information please visit on the official website www.waterpurifier.work